Agni Series 12V, (500VA-700VA)

Our USP:

  • Zero Volt Pickup
  • Ready For Lithium
  • Four Charging Profile for Lithium
  • Mains Reverse Feed Protected
  • Designed For Heavy Load according to Models Rating
  • Low consumption (electrolytic / acid) Technology
  • Optional Remote Monitoring Available
  • Power Saving Technology (Inverter Cost is recovered in 3-4 Years) Optional

PRONTO 12V SOLAR INVERTER AGNI SERIES - SPECIFICATIONS

INVERTER RATING (KVA)500VA700VA
BATTERY VOLTAGE1212
DESIGNLOW FREQ. TRANSFORMER BASED DESIGN
USP OF THE PRODUCTLITHIUM COMPATIBLE READY FOR LITHIUM,LOW ELECTROLYTIC/ACID CONSUMPTION TECHNOLOGY,LEAD ACID BATTERY EQUALISATION MODE,VOLTAGE REGULATION UPTO 165V OPTIONAL 
LITHIUM COMPATIBLE (LITHIUM SPECIAL)4 TYPE CHARGING PROFILE FOR LITHIUM BATTERY
SOLAR CHARGE CONTROLLERTECHNOLOGY-PWM/VOC RANGE 20V-45V/MAX. 60amp
 
ASOLAR CHARGE CONTROLLER SOLAR SECTION
1Charger Type & Topology PWM & MPPT
2PV Total Nominal Capacity (KW) 1KW1KW
3Per Channel PV Capacity (w)(Nominal Peak) 1KW/1.2KW1KW/1.2KW
4Max.VOC for PWM SCC 4545
5Max. Battery Charging Amps From PV (Amps) 20-5020-50
6Battery type Supported LEAD ACID / VRLA / LMLA / LiFePo4
7Min. Battery AH (Suggested) 50100
8Peak charging Efficiency MPPT (%) >92%
    
A.1MPPT Charger Controller  
1No. Of MPPT Channels 11
2Max.Open Circuit PV Volts (Voc) MPPT 5050
3MPPT Voltage Range (Volts) 30-5030-50
4Max.O/P Amps per channel (MPPT Amps) 5555
     
A.2PWM Charger Controller  
1No. Of PWM Channels 11
2PV Minimum Voltage (Volts) PWM 2626
3Max.VOC for PWM SCC 4545
4Max.O/P Amps per channel (PWM Amps) 40/5040/50
     
BBATTERY HIGH/LOW CUT VOLTAGE  
1Lithium (LFP) Low Batt. AlarmPROFILE-111.411.4
2Lithium (LFP) Low Batt. Cut11.211.2
3Lithium (LFP) High Batt./full Charge Cut13.813.8
4Lithium (LFP) Low Batt. AlarmPROFILE-211.411.4
5Lithium (LFP) Low Batt. Cut11.211.2
6Lithium (LFP) High Batt./full Charge Cut1414
7Lithium (LFP) Low Batt. AlarmPROFILE-311.411.4
8Lithium (LFP) Low Batt. Cut11.211.2
9Lithium (LFP) High Batt./full Charge Cut14.214.2
10Lithium (LFP) Low Batt. AlarmPROFILE-411.411.4
11Lithium (LFP) Low Batt. Cut11.211.2
12Lithium (LFP) High Batt./full Charge Cut14.414.4
13Tubular Low Batt. AlarmTUBULAR10.810.8
14Tubular Low Batt. Cut10.510.5
15Tubular High Batt./full Charge Cut14.414.4
16SMF Low Batt. AlarmSMF/VRLA10.810.8
17SMF Low Batt. Cut10.510.5
18SMF High Batt./full Charge Cut1414
 
CINVERTER/ SOLAR PCU  
1No. of Phases/Connection Type 1Phase/2wire
2Nominal Output Voltage/Frequency (Volts/Hz) 220/50hz220/50hz
3Nominal VA Capacity (VA) 500700
4INVERTER LOAD Capacity (W) (BULB LOAD) 400W560W
5Battery Discharging Current (A) 3346
6Voltage Regulation (At No Load) ±2%±2%
7Freq Regulation (At No Load) ±0.5 Hz±0.5 Hz
8THD >4%>4%
9Load Power Factor 0.8 lag to unity
10Over Loads : 100-105% - 60 sec
11105-110% - 30 sec
12110-120% - 2 sec
 
CGRID CHARGER
1Grid Voltage Range (Voltage Sync. Range) 90V-280V (PHASE TO NEUTRAL)
2Grid Frequency Range (Freq.Sync.Range) 50 Hz ±5%
3Max Battery Amps During Grid Charging (Amps) 16A