Prathvi Series 24V, (1.6KVA-2KVA)

Our USP:

  • Zero Volt Pickup
  • Ready For Lithium
  • Four Charging Profile for Lithium
  • Mains Reverse Feed Protected
  • Designed For Heavy Load according to Models Rating
  • Low consumption (electrolytic / acid) Technology
  • Optional Remote Monitoring Available
  • Power Saving Technology (Inverter Cost is recovered in 3-4 Years) Optional

   PRATHVI SERIES - NON SOLAR (HOME UPS) - SPECIFICATIONS

INVERTER RATING (KVA)1600VA2000VA
BATTERY VOLTAGE2424
DESIGNLOW FREQ. TRANSFORMER BASED DESIGN
USP OF THE PRODUCTLITHIUM COMPATIBLE READY FOR LITHIUM,LOW ELECTROLYTIC/ACID CONSUMPTION TECHNOLOGY,LEAD ACID BATTERY EQUALISATION MODE,VOLTAGE REGULATION UPTO 165V OPTIONAL 
LITHIUM COMPATIBLE (LITHIUM SPECIAL)4 TYPE CHARGING PROFILE FOR LITHIUM BATTERY
 
AINVERTER/ SOLAR PCU
1No. of Phases/Connection Type 1Phase/2wire
2Nominal Output Voltage/Frequency (Volts/Hz) 220/50hz220/50hz
3Nominal VA Capacity (VA) 16002000
4INVERTER LOAD Capacity (W) (BULB LOAD) 1.2KW1.6KW
5Battery Discharging Full Load Current (A) 5366
6Voltage Regulation (At No Load) ±2%±2%
7Freq Regulation (At No Load) ±0.5 Hz±0.5 Hz
8THD <4%<4%
9Load Power Factor 0.8 lag  lag to unity
10Over Loads ** : 100-105% - 60 sec
11 105-110% - 30 sec
12 110-120% - 2 sec
     
BBATTERY HIGH/LOW CUT VOLTAGE  
1Lithium (LFP) Low Batt. AlarmPROFILE-122.822.8
2Lithium (LFP) Low Batt. Cut22.422.4
3Lithium (LFP) High Batt./full Charge Cut27.627.6
4Lithium (LFP) Low Batt. AlarmPROFILE-222.822.8
5Lithium (LFP) Low Batt. Cut22.422.4
6Lithium (LFP) High Batt./full Charge Cut2828
7Lithium (LFP) Low Batt. AlarmPROFILE-322.822.8
8Lithium (LFP) Low Batt. Cut22.422.4
9Lithium (LFP) High Batt./full Charge Cut28.428.4
10Lithium (LFP) Low Batt. AlarmPROFILE-422.822.8
11Lithium (LFP) Low Batt. Cut22.422.4
12Lithium (LFP) High Batt./full Charge Cut28.828.8
13Tubular Low Batt. AlarmTUBULAR21.621.6
14Tubular Low Batt. Cut2121
15Tubular High Batt./full Charge Cut28.828.8
16SMF Low Batt. AlarmSMF/VRLA21.621.6
17SMF Low Batt. Cut2121
18SMF High Batt./full Charge Cut2828
  
CGRID CHARGER
1Grid Voltage Range (Inverter Mode) 90V-280V (PHASE TO NEUTRAL)
2Grid Voltage Range (UPS Mode) 180V-265V (PHASE TO NEUTRAL)
3Grid Frequency Range (Freq.Sync.Range) 50 Hz ± 5%
4Max Battery Amps During Grid Charging (Amps) 16A16A