(60KVA - 120KVA) 3P OFF GRID HYBRID INVERTER

Our USP:

Bi DirectionalSeamless switching to and from grid (both import and export) and batterysupply, high-efficiency MPPT technology
GRID-INTERACTIVEBlends solar and grid- power for optimisation
IEC CERTIFIEDIEC certifications available
PURE SINE WAVETECHNOLOGYRecommended for longer life of Industrial/Commercial equipment
INTELLIGENT BATTERYCHARGING3-Stage charging (Float, Bulk & Absorption) for more battery life (for LeadAcid batteries). Communication-based charging for Lithium chemistriesavailable
COMPATIBLE CHARGER SupportsSupports wide range of batteries-Flooded Lead Acid Tubular/GEL/VRLA. Onrequest product for Li+

PRONTO RENEWABLES ENERGY PVT LTD

PRONTO 3P SOLAR OFF GRID/HYBRID INVERTER - SPECIFICATIONS
INVERTER RATING (KVA)60KVA80KVA100KVA100KVA120KVA
BATTERY VOLTAGE360V480V360V480V360
SOLAR CHARGE CONTROLLERTECHNOLOGY-MPPT/VOC RANGE 415-900VTECHNOLOGY-MPPT/VOC RANGE 552-900VTECHNOLOGY-MPPT/VOC RANGE 415-900VTECHNOLOGY-MPPT/VOC RANGE 552-900VTECHNOLOGY-MPPT/VOC RANGE 415-900V
ASOLAR CHARGE CONTROLLER     
1Charger Type & TopologyBuck Type MPPT
2PV Total Nominal Capacity (KW)60 KW80KW100KW100KW120KW
3Per Channel PV Capacity (w)(Nominal Peak)60KW/66KW80KW/88KW100KW/110KW100KW/110KW120KW/132KW
4PV Minimum Voltage (Volts)415552415552415
5Max. I/P Amps per channel (Amps)5545615775
6Max. Battery Amps during PV charging125125210158250
7Battery type SupportedVRLA / LMLA / Li-ion/ LiFePo4 (User Settable)
8Min. Battery AH (Suggested)300300300300300
9Peak charging Efficiency MPPT (%)>93%>93%>93%>93%>93%
       
A.1MPPT Charger Controller     
1No. Of MPPT Channels23333
2Max.Open Circuit PV Volts (Voc) MPPT900900900900900
3MPPT Voltage Range (Volts)415-900552-900415-900552-900415-900
4Max. SCC O/P (Amps)125125210158250
       
BSOLAR INVERTER     
1No. of Phases/Connection Type3Phase/4 wire
2Nominal KW Capacity (KW) (Tortal Per Phase)(*4)48.0/16.064.0/21.380.0/26.680.0/26.696.0/32.0
3Nominal Battery Voltage360480360480480
4Nominal Output Voltage/ Frequency (Volts/Hz)415/50415/50415/50415/50415/50
5Output Amp per Phase (*4)69.692.6115.6115.6139.1
6Voltage Regulation (in Standalone Mode)± 2%± 2%± 2%± 2%± 2%
7Freq. Regulation (in Standalone Mode)± 0.5 Hz± 0.5 Hz± 0.5 Hz± 0.5 Hz± 0.5 Hz
8THD<3%<3%<3%<3%<3%
9Load Power Factor0.8 lag to unity
10Efficiency (%): Peak/ 100% Load/25% Load >92/ >90/ >85>92/ >90/ >85>92/ >90/ >85>92/ >90/ >85>92/ >90/ >85
11Over Loads :100-110% - 60 sec
12110-125% - 30 sec
13125-150% - 5 sec
14Max Alowed Phase Imbalnce (%)100%100%100%100%100%
15Auto Bypass FeatureProvidedProvidedProvidedProvidedProvided
16Parallel Operation with grid/DGProvidedProvidedProvidedProvidedProvided
17Power Export to Grid Facility Enable/Disable)Enable/Disable (User Settable)
18Anti Islanding from GridProvidedProvidedProvidedProvidedProvided
 
CGRID CHARGER
1Grid Voltage Range (Voltage Sync. Range)160V-280V (Phase to Neutral)
2Grid Frequency Range (Freq. Sync. Range)50 Hz ± 5%
3Max. Grid Import Power (KW)48KW64KW80KW80KW96KW
4Peak charging Efficiency (%)>87>87>87>87>87
5Max Battery Amps During Grid Charging (Amps)9595157.8118189