40KVA/ 240V 3P MPPT Inverter
Our USP:
Bi Directional | Seamless switching to and from grid (both import and export) and batterysupply, high-efficiency MPPT technology |
GRID-INTERACTIVE | Blends solar and grid- power for optimisation |
IEC CERTIFIED | IEC certifications available |
PURE SINE WAVETECHNOLOGY | Recommended for longer life of Industrial/Commercial equipment |
INTELLIGENT BATTERYCHARGING | 3-Stage charging (Float, Bulk & Absorption) for more battery life (for LeadAcid batteries). Communication-based charging for Lithium chemistriesavailable |
COMPATIBLE CHARGER Supports | Supports wide range of batteries-Flooded Lead Acid Tubular/GEL/VRLA. Onrequest product for Li+ |
PRONTO RENEWABLES ENERGY PVT LTD | ||
PRONTO 40KVA SOLAR INVERTER AGNI SERIES - SPECIFICATIONS | ||
INVERTER RATING (KVA) | 40KVA | |
BATTERY VOLTAGE | 240V | |
SOLAR CHARGE CONTROLLER | TECHNOLOGY-MPPT/VOC RANGE 275-7000V/MAX. 125Amp | |
A | SOLAR CHARGE CONTROLLER | |
1 | Charger Type & Topology | Buck Type MPPT |
2 | PV Total Nominal Capacity (KW) | 40 KW |
3 | Per Channel PV Capacity (w)(Nominal Peak) | 40KW/44KW |
PV Minimum Voltage (Volts) | 275 | |
4 | Max. Battery Charging Amps during PV Charging (Amps) | 125 |
5 | Battery type Supported | VRLA / LMLA / Li-ion/ LiFePo4 (User Settable) |
6 | Min. Battery AH (Suggested) | 300 |
7 | Peak charging Efficiency MPPT (%) | >93% |
A.1 | MPPT Charger Controller | |
1 | No. Of MPPT Channels | 2 |
2 | Max.Open Circuit PV Volts (Voc) MPPT | 700 |
3 | MPPT Voltage Range (Volts) | 275-700 |
Max.I/P Amps per channel (Amps) | 50 | |
4 | Max. SCC O/P (Amps) | 125 |
B | SOLAR INVERTER | |
1 | No. of Phases/Connection Type | 3Phase/4 wires |
Nominal Battery Voltage (Volts) | 240 | |
2 | Nominal Output Voltage/Frequency (Volts/Hz) | 415/50hz |
3 | Nominal KW Capacity (KW) (Total Per Phase) (*4) | 32/10.7 |
4 | Output Amps Per Phase (*4) | 46.4 |
5 | Voltage Regulation (in Standalone Mode) | ±2% |
6 | Freq. Regulation (in Standalone Mode) | ±0.5 Hz |
7 | Inverter Load Capacity (W) (BULB LOAD) | 1.2KW |
9 | THD | <3% |
10 | Load Power Factor | 0.8 lag to unity |
11 | Efficiency (%): Peak/100% Load/25% Load | >92/ >90/ >85 |
12 | Over Loads : | 100-110% - 60 sec |
13 | 110-125% - 30 sec | |
14 | 125-150% - 5 sec | |
15 | Max Alowed Phase Imbalnce (%) | 100% |
16 | Auto Bypass Feature | Provided |
17 | Parallel Operation with grid/DG | Provided |
18 | Power Export to Grid Facility Enable/Disable) | Enable/Disable (User Settable) |
19 | Anti Islanding from Grid | Provided |
C | GRID CHARGER | |
1 | Grid Voltage Range (Voltage Sync. Range) | 160V-280V (Phase to Neutral) |
2 | Grid Frequency Range (Freq. Sync. Range) | 50 Hz ± 5% |
3 | Max. Grid Import Power (KW) | 32 (KW) |
4 | Max. Battery Amps During Grid Charging (Amps) | 95 |
5 | Peak charging Efficiency (%) | >87 |