AGNI 96V (10KVA MPPT PCU)
Our USP:
- Zero Volt Pickup
- Ready For Lithium
- Four Charging Profile for Lithium
- Mains Reverse Feed Protected
- Designed For Heavy Load according to Models Rating
- Low consumption (electrolytic / acid) Technology
- Optional Remote Monitoring Available
- Power Saving Technology (Inverter Cost is recovered in 3-4 Years) Optional
PRONTO RENEWABLES ENERGY PVT LTD | |||
PRONTO SOLAR INVERTER AGNI SERIES - SPECIFICATIONS | |||
INVERTER RATING (KVA) | 10KVA | ||
BATTERY VOLTAGE | 96 | ||
A | SOLAR CHARGE CONTROLLER | ||
1 | Charger Type & Topology | MPPT | |
2 | PV Total Nominal Capacity (KVA) | 10KW | |
3 | Per Channel PV Capacity (w)(Nominal Peak) | 10KW | |
4 | Max. Battery Charging Amps From PV (Amps) | 50 | |
5 | Battery type Supported | LEAD ACID / VRLA / LMLA / LiFePo4 | |
6 | Min. Battery AH (Suggested) | 100 | |
7 | Peak charging Efficiency MPPT (%) | >92% | |
MPPT Charger Controller | |||
1 | No. Of MPPT Channels | 1 | |
2 | Max.Open Circuit PV Volts (Voc) MPPT | 200 | |
3 | MPPT Voltage Range (Volts) | 135-200 | |
4 | Max.O/P Amps per channel (MPPT Amps) | 80A | |
B | BATTERY HIGH/LOW CUT VOLTAGE | ||
1 | Lithium (LFP) Low Batt. Alarm | PROFILE-1 | 91.2 |
2 | Lithium (LFP) Low Batt. Cut | 89.6 | |
3 | Lithium (LFP) High Batt./full Charge Cut | 110.4 | |
4 | Lithium (LFP) Low Batt. Alarm | PROFILE-2 | 91.2 |
5 | Lithium (LFP) Low Batt. Cut | 89.6 | |
6 | Lithium (LFP) High Batt./full Charge Cut | 112 | |
7 | Lithium (LFP) Low Batt. Alarm | PROFILE-3 | 91.2 |
8 | Lithium (LFP) Low Batt. Cut | 89.6 | |
9 | Lithium (LFP) High Batt./full Charge Cut | 113.6 | |
10 | Lithium (LFP) Low Batt. Alarm | PROFILE-4 | 91.2 |
11 | Lithium (LFP) Low Batt. Cut | 89.6 | |
12 | Lithium (LFP) High Batt./full Charge Cut | 115.2 | |
13 | Tubular Low Batt. Alarm | TUBULAR | 86.4 |
14 | Tubular Low Batt. Cut | 84 | |
15 | Tubular High Batt./full Charge Cut | 115.2 | |
16 | SMF Low Batt. Alarm | SMF/VRLA | 86.4 |
17 | SMF Low Batt. Cut | 84 | |
18 | SMF High Batt./full Charge Cut | 112 | |
C | INVERTER/ SOLAR PCU | ||
1 | No. of Phases/Connection Type | 1Phase/2wires | |
2 | Nominal Output Voltage/Frequency (Volts/Hz) | 220/50hz | |
3 | Nominal VA Capacity (VA) | 10000 | |
4 | INVERTER LOAD Capacity (W) (BULB LOAD) | 8KW | |
5 | Battery Discharging Current (A) | 83.3 | |
6 | Voltage Regulation (At No Load) | ±2% | |
7 | Freq Regulation (At No Load) | ±0.5 Hz | |
8 | THD | >4% | |
9 | Load Power Factor | 0.8 lag to unity | |
10 | Over Loads : | 100-105% - 60 sec | |
11 | 105-110% - 30 sec | ||
12 | 110-120% - 2 sec | ||
D | GRID CHARGER | ||
1 | Grid Voltage Range (Voltage Sync. Range) | 90V-280V (PHASE TO NEUTRAL) | |
2 | Grid Frequency Range (Freq.Sync.Range) | 50 Hz ±5% | |
3 | Max Battery Amps During Grid Charging (Amps) | 20A |