AGNI 48V (3.5KVA-5KVA)
Our USP:
- Zero Volt Pickup
- Ready For Lithium
- Four Charging Profile for Lithium
- Mains Reverse Feed Protected
- Designed For Heavy Load according to Models Rating
- Low consumption (electrolytic / acid) Technology
- Optional Remote Monitoring Available
- Power Saving Technology (Inverter Cost is recovered in 3-4 Years) Optional
PRONTO 48V SOLAR INVERTER AGNI SERIES - SPECIFICATIONS | |||
| INVERTER RATING (KVA) | 3500VA | 5000VA | |
| BATTERY VOLTAGE | 48 | 48 | |
| A | SOLAR CHARGE CONTROLLER | ||
| 1 | Charger Type & Topology | MPPT | |
| 2 | PV Total Nominal Capacity (KW) | 4KW | 5KW |
| 3 | Per Channel PV Capacity (w)(Nominal Peak) | 4KW | 5.2KW |
| 5 | Max. Battery Charging Amps From PV (Amps) | 200 | 200 |
| 6 | Battery type Supported | 150 | 150 |
| 8 | Peak charging Efficiency MPPT (%) | >92% | |
| MPPT Charger Controller | |||
| 1 | No. Of MPPT Channels | 1 | 2 |
| 2 | Max.Open Circuit PV Volts (Voc) MPPT | 200 | 200 |
| 3 | MPPT Voltage Range (Volts) | 90-180 | 90-180 |
| 4 | Max.O/P Amps per channel (MPPT Amps) | 60 | 60/120 |
| B | INVERTER/ SOLAR PCU | ||
| 1 | No. of Phases/Connection Type | 1Phase/2wire | |
| 2 | Nominal Output Voltage/Frequency (Volts/Hz) | 220/50hz | 220/50hz |
| 3 | Nominal VA Capacity (VA) | 3500 | 5000 |
| 4 | INVERTER LOAD Capacity (W) (BULB LOAD) | 2.8KW | 4KW |
| 5 | Battery Discharging Current (A) | 58 | 100 |
| 6 | Voltage Regulation (At No Load) | ±2% | ±2% |
| 7 | Freq Regulation (At No Load) | ±0.5 Hz | ±0.5 Hz |
| 8 | THD | >4% | >4% |
| 9 | Load Power Factor | 0.8 lag to unity | |
| 10 | Over Loads : | 100-105% - 60 sec | |
| 11 | 105-110% - 30 sec | ||
| 12 | 110-120% - 2 sec | ||
| C | GRID CHARGER | ||
| 1 | Grid Voltage Range (Voltage Sync. Range) | 90V-280V (PHASE TO NEUTRAL) | |
| 2 | Grid Frequency Range (Freq.Sync.Range) | 50 Hz ±5% | |
| 3 | Max Battery Amps During Grid Charging (Amps) | 16A | |